Theses/Dissertations
Author Wieberg, Kandi Rebecca.

Title Field investigation of spalling in bridge decks with partial-depth precast concrete panel systems using non-destructive testing / by Kandi Rebecca Wieberg.

Published ©2010.
LOCATION CALL # STATUS
 MST DEPOSITORY  THESIS T 9660/9692  MICROFILM    NOT CHECKED OUT
 MST Thesis  THESIS T 9692    NOT CHECKED OUT
Description xii, 146 leaves : illustrations ; 28 cm + 1 CD-ROM.
Notes System requirements: Adobe Acrobat Reader.
Summary "This study involved the investigation of the causes of spalling observed in several partial-depth precast prestressed bridge decks in the state of Missouri. Recently it has been observed that several bridges in Missouri with this type of construction have experienced spalling of concrete at the edges of the panels revealing an extreme condition of corrosion in the prestressing tendons, some to the point of rupture. Ground penetrating radar (GPR), which has been shown to be successful in bridge deck evaluation, was used to determine the relative condition of the prestressing tendons as well as the relative condition of the concrete throughout the deck in order to identify areas of cracking and corrosion. Particular techniques were used in an attempt to identify areas of delamination at the interface between the precast panels and cast-in-place topping slab, namely the acquisition of data from both the top and bottom deck surfaces as well as specialized data interpretation techniques. Core control and visual inspection were utilized to interpret and validate the GPR data. Half-cell, resistivity and rebound hammer testing was performed on bridge deck panels to determine the corrosion levels of the prestressing strands and material properties of the panels. Findings indicate that spalling in the PPC panels is the result of the penetration of water and chlorides through the reflective cracking in the CIP topping, to the interface between the CIP topping and the PPC panels, then through the PPC panels to the prestressing tendons located near the panel joints. Increased crack control in the CIP topping delays the onset of spalling at the panel joints. Most deterioration is occurring near the area of reflective cracking in the CIP topping and not in the area of concrete over the middle of the panels. Some delamination is occurring at the CIP topping and panel interface"--Abstract, leaf iii.
Notes Vita.
CD-ROM contains appendixes - Transverse, Longitudinal, and Panel.
M.S. Missouri University of Science and Technology 2010.
Includes bibliographical references (leaves 142-144).
Subjects Concrete bridges -- Deterioration -- Missouri -- Evaluation.
Concrete bridges -- Nondestructive testing.
Ground penetrating radar.
Other Titles MST thesis. Civil Engineering (M.S., 2010).
OCLC/WorldCat Number 692199097
Author Wieberg, Kandi Rebecca.
Title Field investigation of spalling in bridge decks with partial-depth precast concrete panel systems using non-destructive testing / by Kandi Rebecca Wieberg.
Subjects Concrete bridges -- Deterioration -- Missouri -- Evaluation.
Concrete bridges -- Nondestructive testing.
Ground penetrating radar.
Other Titles MST thesis. Civil Engineering (M.S., 2010).